Abstract :
A novel hydrogen-fueled power plant with inherent CO2 capture based on calcium looping process is proposed in this paper. The analyzed system has been evaluated from the energy and exergy points of view, it enables determination of the contribution of main component to the total exergy loss. The results show that energy and exergy efficiencies of the system are 42.7% and 42.25% respectively, combustion chamber and regenerator are responsible for large exergy destructions, mainly due to irreversibilities associated with the combustion reactions, they have great potential for system efficiencies improvements. The effects of various air pressure ratios and gas turbine inlet temperatures on the system thermodynamic performance are also presented. The thermodynamic efficiencies increase with the increase in air pressure ratios and gas turbine inlet temperatures.
Keywords :
Hydrogen production , coal gasification , Calcium sorbent , CO2 capture