Title of article :
A comparison of direct methanol fuel cell degradation under different modes of operation
Author/Authors :
Wongyao، نويسنده , , Nutthapon and Therdthianwong، نويسنده , , Apichai and Therdthianwong، نويسنده , , Supaporn and Senthil Kumar، نويسنده , , S.M. and Scott، نويسنده , , Keith، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
10
From page :
9464
To page :
9473
Abstract :
The degradation test of direct methanol fuel cells (DMFCs) under on–off operation with variable load profile, known as a variable load on-off operation (VLOO) mode, was compared to continuous operation with a constant load, known as a constant load continuous operation (CLCO) mode. It was found that the performance loss in the VLOO mode was higher than that under the CLCO mode in terms of open circuit voltage drop (3.6 times higher) and the maximum power density reduction rate (1.23 times greater). Under both operation modes, the anode catalyst was deteriorated by Ru dissolution. However, the faster decay of cell performance under VLOO mode was mainly caused by the increase of cathode polarization due to higher methanol crossover and the decrease of Pt activity to the oxygen reduction reaction induced by Ru deposition.
Keywords :
Methanol crossover , Direct methanol fuel cell , Constant load continuous operation mode , Variable load on-off operation mode , Ru dissolution , Cell performance loss
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2013
Journal title :
International Journal of Hydrogen Energy
Record number :
1863760
Link To Document :
بازگشت