Title of article :
Supraspinatus tears: Propagation and strain alteration
Author/Authors :
Reilly، نويسنده , , Peter and Amis، نويسنده , , Andrew A. and Wallace، نويسنده , , Andrew L. and Emery، نويسنده , , Roger J.H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
It was hypothesized that there would be an alteration in strain when macroscopically normal supraspinatus tendons were subjected to three patterns of surgically created tear. The propagation of joint-side partial-thickness tears was also examined. Cadaveric shoulders were tested on a purpose-built rig with static loading from 20 to 200 N and during glenohumeral abduction from 0° to 120° with a 100-N tensile load. Differential variable reluctance transducers were used to calculate strain. Six-millimeter-wide midsubstance full-thickness tears (n = 2) caused an increase in bursal-side strain both with abduction 1.93% (90°) and with loading 0.33% (150 N). Intratendinous delamination (n = 2) increased joint-side strain during abduction and bursal-side strain with loading. A 2-mm-deep tear across the tendon insertion (n = 5) increased the bursal-side strain in abduction by 3.54% (120°) and with load by 2.53% (200 N). Tear propagation was observed from joint to bursal sides during abduction. Tendon failure occurred at the insertion. (J Shoulder Elbow Surg 2003;12:134-8)
Journal title :
Journal of Shoulder and Elbow Surgery
Journal title :
Journal of Shoulder and Elbow Surgery