Title of article
Early complications of operatively treated proximal humeral fractures
Author/Authors
Smith، نويسنده , , Adam M. and Mardones، نويسنده , , Rodrigo M. and Sperling، نويسنده , , John W. and Cofield، نويسنده , , Robert H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
11
From page
14
To page
24
Abstract
Minimal information exists regarding early complications after operatively treated proximal humeral fractures. Of the 82 shoulders that had osteosynthesis, 42 had a (nonmedical) complication, with 21 requiring further surgery. Of 42 shoulders with complications, 12 were related to incomplete reduction, 16 had loss of anatomic fracture fixation, 9 had delayed healing, 3 had an infection, 1 had rotator cuff failure, and 1 had loose bodies. Fixed-angle plates had lower rates of initial malpositioning and resultant malunion. Of the 22 shoulders requiring hemiarthroplasty, 14 had an early complication. Of these, 7 had complications relating to implant insertion or tuberosity malreduction at the index operation and 7 had problems with tuberosity healing. The rate of complications after operative treatment of proximal humeral fractures is high. All efforts at fracture fragment fixation with osteosynthesis and hemiarthroplasty should be directed at obtaining anatomic fracture fixation that resists displacement.
Journal title
Journal of Shoulder and Elbow Surgery
Serial Year
2007
Journal title
Journal of Shoulder and Elbow Surgery
Record number
1867382
Link To Document