Title of article
Efficacy of interference screw and double-docking methods using palmaris longus and GraftJacket for medial collateral ligament reconstruction of the elbow
Author/Authors
Furukawa، نويسنده , , Keizo and Pichora، نويسنده , , Jamie and Steinmann، نويسنده , , Scott and Faber، نويسنده , , Kenneth J. and Johnson، نويسنده , , James A. and King، نويسنده , , Graham J.W.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
449
To page
453
Abstract
Single-strand elbow medial collateral ligament reconstruction strength was evaluated by use of double-docking and interference screw methods with either a palmaris longus tendon or GraftJacket as the reconstruction material. Thirteen upper extremities were mounted in 90° of valgus orientation and subjected to cyclic valgus loading that increased progressively until failure occurred. The double-docking reconstructions outperformed the interference screw reconstructions (P < .05), whereas the palmaris longus and GraftJacket performed comparably (P > .05). The favorable initial strength of the GraftJacket make it a potentially viable alternative to the use of autogenous palmaris longus tendons; however, further studies are required to evaluate graft strength during healing. The clinical use of the double-docking technique of single-strand medial collateral ligament reconstruction should be considered because of its simplicity and initial strength.
Journal title
Journal of Shoulder and Elbow Surgery
Serial Year
2007
Journal title
Journal of Shoulder and Elbow Surgery
Record number
1867532
Link To Document