Title of article :
Biomechanical evaluation of a pre-contoured clavicle plate
Author/Authors :
Goswami، نويسنده , , Tarun and Markert، نويسنده , , Ronald J. and Anderson، نويسنده , , Christopher G. and Sundaram، نويسنده , , Sandhya S. and Crosby، نويسنده , , Lynn A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
4
From page :
815
To page :
818
Abstract :
Recent attention has been focused on the operative treatment of mid-shaft fractures of the clavicle. This study compares the in-vitro biomechanical properties of a pre-formed titanium clavicle plate (Acumed) to a Synthes 3.5 mm limited-contact dynamic-compression (LCDC) plate using a cadaveric osteotomy model. An osteotomy was performed on 7 pairs of human clavicles and were randomly plated with either a Synthes 3.5 mm LCDC stainless steel plate or an Acumed titanium pre-contoured clavicle plate. After plating, specimens were tested on an EnduraTEC material testing apparatus for axial compression and tension strength, as well as torsional strength in compression and tension. Biomechanical test results for plated specimens are reported for the LCDC plate and the Acumed plate, and the 2 plates are compared. xploratory study supports investigations with larger sample sizes to determine if the pre-contoured plate differs from the LCDC plate in biomechanical properties and the al implications of such differences.
Journal title :
Journal of Shoulder and Elbow Surgery
Serial Year :
2008
Journal title :
Journal of Shoulder and Elbow Surgery
Record number :
1867926
Link To Document :
بازگشت