• Title of article

    Effects of shoulder position on axillary nerve positions during the split lateral deltoid approach

  • Author/Authors

    Cheung، نويسنده , , Sunny and Fitzpatrick، نويسنده , , Michael and Lee، نويسنده , , Thay Q.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    748
  • To page
    755
  • Abstract
    Background illary nerve may be injured during percutaneous fixation of proximal humerus fractures. This study investigated the kinematic behavior of the superior and inferior borders of the axillary nerve under varying shoulder positions. This information may reduce iatrogenic neurologic injury during fracture reduction and hardware placement. s teral deltoid approach was performed on 7 fresh frozen shoulders. The inferior and superior borders of the axillary nerve were tagged. Screws were placed in the anterior, middle, and posterior acromion as landmarks. Three-dimensional distances of the inferior and superior border of the nerve were measured to the mid-acromion while the shoulder was placed in combinations of forward flexion, vertical abduction, and humeral rotation. The distances were compared by repeated measures ANOVA statistical analysis. s stance from the mid-acromion to the superior border of the axillary nerve was 66.6 mm (±5.7), and to the inferior axillary nerve was 75.7 mm (±5.8) with the shoulder in neutral position. Vertical abduction to 60° significantly moved the superior and inferior borders of the axillary nerve to a distance of 53.9 (±7.7) and 61.6 mm (±8.1), respectively (P < 0.005). Forward flexion had no significant effect on the position of the axillary nerve (P > 0.5). The longest distance from the mid-acromion to the inferior border of the axillary nerve was 86 mm with the arm forward flexed. sions in determinant of axillary nerve position with respect to the acromion is vertical abduction. Axillary nerve position is essentially unaffected by varying degrees of humeral rotation and forward flexion. Vertical glenohumeral abduction to 60° is required to move the nerve significantly closer to the acromion. of Evidence science anatomic study.
  • Keywords
    Axillary nerve , proximal humeral fractures , iatrogenic nerve injury , hardware placement , fracture reduction
  • Journal title
    Journal of Shoulder and Elbow Surgery
  • Serial Year
    2009
  • Journal title
    Journal of Shoulder and Elbow Surgery
  • Record number

    1868244