Title of article :
Tetracycline labeling as a measure of humeral head viability after 3- or 4-part proximal humerus fracture
Author/Authors :
Crosby، نويسنده , , Lynn A. and Finnan، نويسنده , , Ryan P. and Anderson، نويسنده , , Christopher G. and Gozdanovic، نويسنده , , Jon F. Miller، نويسنده , , Mill W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
8
From page :
851
To page :
858
Abstract :
Hypothesis ically located humeral head biopsies from three-part proximal humerus fractures taken at the time of hemiarthroplasty will show greater tetracycline labeling under fluorescent microscopy than those biopsies taken from four-part fractures. Additionally, biopsies from younger patients would show greater fluorescence than older patients. al and methods en consecutive adult patients (range 43-83 years) underwent hemiarthroplasty as definitive treatment for 20 displaced three- and four-part proximal humerus fractures after having received 500mg of tetracycline hydrochloride orally every six hours for the immediate five preoperative days. Humeral head biopsies were taken from four pre-determined locations intraoperatively. The biopsies were prepared and analyzed with fluorescent microscopy. s ecimens in each biopsy location demonstrated fluorescence. There was no difference between the mean rank gray values for the four biopsy locations (p = 0.78 with the Friedman test). There was no difference between the mean rank gray values for the four biopsy locations when analyzed according to three-part vs four-part fracture (p > 0.05 with the Mann-Whitney test). There was an inverse relationship between age and fluorescence for the anterosuperior biopsy location (p = 0.033 with Spearman correlation). sion ar supply is preserved in displaced three- and four-part proximal humerus fractures. With intact vascularity to the humeral head, head-preserving techniques utilizing stable, site-specific fixation and minimal dissection should be considered in the treatment of displaced three- and four-part proximal humerus fractures. sion ar supply is preserved in displaced three- and four-part proximal humerus fractures, especially in younger patients in the anterosuperior aspect of the humeral head. of evidence Science Study.
Keywords :
Hemiarthroplasty , three-part , four-part , Proximal humerus fracturel , Avascular necrosis , Tetracycline labeling
Journal title :
Journal of Shoulder and Elbow Surgery
Serial Year :
2009
Journal title :
Journal of Shoulder and Elbow Surgery
Record number :
1868274
Link To Document :
بازگشت