Title of article :
Midterm results of a total shoulder prosthesis fixed with a cementless glenoid component
Author/Authors :
Montoya، نويسنده , , Fredy and Magosch، نويسنده , , Petra and Scheiderer، نويسنده , , Bastian and Lichtenberg، نويسنده , , Sven and Melean، نويسنده , , Patricio and Habermeyer، نويسنده , , Peter، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
628
To page :
635
Abstract :
Background m of this study was to evaluate the midterm results and complications of a total shoulder arthroplasty implanted with a metal-backed, bone-ingrowth glenoid component. als and methods al, 62 patients (65 shoulders) diagnosed with primary osteoarthritis were treated with total shoulder arthroplasty with a cementless glenoid component. The mean age was 66 years (range, 54-85 years). Fifty-three patients were evaluated after a mean of 64 months (range, 26-85 months). Functional results were documented by use of the age- and sex-adjusted Constant score. Radiolucent line (RLL) assessment of the glenoid component was performed by use of true anteroposterior and axillary views. s nstant score improved significantly from 49% preoperatively to 89.8% postoperatively (P < .0001). Active range of motion improved significantly for flexion (from 118° to 146°), abduction (from 87° to 133°), and external rotation (from 21° to 44°) (P < .0001). In 3 cases (5.7%), RLLs of 1 mm or less were present, and 1 case (1.8%) had an RLL of 2 mm or less in 1 zone. Glenoid component loosening occurred in 5 cases (9.4%) because of breakage of the cage screw. Four of these patients presented preoperatively with a type B1 glenoid and one patient with type A2. Two of the patients who underwent revision also had a complete tear of the rotator cuff. The revision rate was 11.3% (6 patients) after a mean of 68 months. sion midterm follow-up, clinical outcomes of patients operated on with a cementless, metal-backed glenoid implant improved significantly. However, an unacceptable rate of complications and revisions was found. Glenoid loosening predominantly occurred in patients with preoperative eccentric glenoid morphology and was also related to cranial migration of the proximal humerus during the follow-up period.
Keywords :
Total shoulder arthroplasty , cementless glenoid component , Bone ingrowth , shoulder osteoarthritis , radiolucent lines , Loosening
Journal title :
Journal of Shoulder and Elbow Surgery
Serial Year :
2013
Journal title :
Journal of Shoulder and Elbow Surgery
Record number :
1869895
Link To Document :
بازگشت