Title of article :
Biomechanical testing of small versus large lesser tuberosity osteotomies: effect on gap formation and ultimate failure load
Author/Authors :
Fishman، نويسنده , , Matthew P. and Budge، نويسنده , , Matthew D. and Moravek Jr.، نويسنده , , James E. and Mayer، نويسنده , , Mark and Kurdziel، نويسنده , , Michael D. and Baker، نويسنده , , Kevin C. and Wiater، نويسنده , , J. Michael، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
Background
pularis muscle dysfunction after total shoulder arthroplasty (TSA) can be a devastating complication. Recent biomechanical and clinical results suggest the superiority of lesser tuberosity osteotomy (LTO) over subscapularis tenotomy; however, disagreement over the best repair technique remains. This study aimed to characterize the strength of 2 novel repair techniques for LTO fixation compared with standard tenotomy and dual-row tuberosity osteotomies during TSA.
s
fresh frozen cadaveric shoulders were dissected of all soft tissues except the humeri and attached subscapularis myotendinous unit. Humeri and subscapularis muscle belly were secured to a materials testing frame and subjected to cyclic loading, followed by load to failure for characterization of gap formation, ultimate failure load, and mechanism of failure. Repair techniques investigated were traditional subscapularis tenotomy and dual-row fleck LTO compared with novel techniques of single-cable and 2-suture large LTO repairs.
s
nificant difference in ultimate failure load was noted among the repair techniques (P = .565). The tenotomy repair (6.0 ± 3.9 mm) displayed significantly greater gapping in response to increasing load than LTO repair techniques (P < .05). No significant difference was noted between any LTO repairs at specific loads during cyclic testing (P > .05).
sion
udy displayed superior repair integrity of LTO vs tenotomy repairs. The advantages of the 2-suture large LTO technique over other LTO techniques include its simple technique, with a minimum amount of suture, avoidance of metallic hardware, and greater access to the glenoid, while providing comparable repair stability. Further research is warranted to fully evaluate these new techniques.
Keywords :
lesser tuberosity osteotomy , Biomechanical evaluation , subscapularis tenotomy , Total shoulder arthroplasty
Journal title :
Journal of Shoulder and Elbow Surgery
Journal title :
Journal of Shoulder and Elbow Surgery