Title of article :
Accuracy and reliability testing of two methods to measure internal rotation of the glenohumeral joint
Author/Authors :
Hall، نويسنده , , Justin M. and Azar، نويسنده , , Frederick M. and Miller III، نويسنده , , Robert H. and Smith، نويسنده , , Richard and Throckmorton، نويسنده , , Thomas W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
1296
To page :
1300
Abstract :
Background pared accuracy and reliability of a traditional method of measurement (most cephalad vertebral spinous process that can be reached by a patient with the extended thumb) to estimates made with the shoulder in abduction to determine if there were differences between the two methods. s ysicians with fellowship training in sports medicine or shoulder surgery estimated measurements in 48 healthy volunteers. Three were randomly chosen to make estimates of both internal rotation measurements for each volunteer. An independent observer made objective measurements on lateral scoliosis films (spinous process method) or with a goniometer (abduction method). Examiners were blinded to objective measurements as well as to previous estimates. s lass coefficients for interobserver reliability for the traditional method averaged 0.75, indicating good agreement among observers. The difference in vertebral level estimated by the examiner and the actual radiographic level averaged 1.8 levels. The intraclass coefficient for interobserver reliability for the abduction method averaged 0.81 for all examiners, indicating near-perfect agreement. Confidence intervals indicated that estimates were an average of 8° different from the objective goniometer measurements. Pearson correlation coefficients of intraobserver reliability for the abduction method averaged 0.94, indicating near-perfect agreement within observers. Confidence intervals demonstrated repeated estimates between 5° and 10° of the original. sions al rotation estimates made with the shoulder abducted demonstrated interobserver reliability superior to that of spinous process estimates, and reproducibility was high. On the basis of this finding, we now take glenohumeral internal rotation measurements with the shoulder in abduction and use a goniometer to maximize accuracy and objectivity.
Keywords :
accuracy , Glenohumeral joint , internal rotation , Measurement , spinous process method , abduction method
Journal title :
Journal of Shoulder and Elbow Surgery
Serial Year :
2014
Journal title :
Journal of Shoulder and Elbow Surgery
Record number :
1870810
Link To Document :
بازگشت