Author/Authors :
Abizaid، نويسنده , , Alexandre and Kornowski، نويسنده , , Ran and Mintz، نويسنده , , Gary D. and Hong، نويسنده , , Mun K and Picahrd، نويسنده , , Augusto D. and Kent، نويسنده , , Kenneth M. and Satler، نويسنده , , Lowell F. and Popma، نويسنده , , Jeffrey J and Bramwell، نويسنده , , Orville and Leon، نويسنده , , Martin B، نويسنده ,
Abstract :
The impact of guiding catheter selection on the measurement of coronary flow reserve was assessed by injecting increasing doses of adenosine through 3 different catheters often used during coronary interventions. When guiding catheters with side holes were used, an approximate doubling of the adenosine dose was required to produce a coronary flow reserve response similar to a 12-μg dose of adenosine injected through guiding catheters without side holes.