Title of article :
Usefulness of transthoracic echocardiography in demonstrating coronary blood flow after coronary artery bypass grafting
Author/Authors :
Kit-Chong Ng، نويسنده , , Daniel Wing and Vlachonassios، نويسنده , , Konstantinos and Nimalasuriya، نويسنده , , Anoshie R. and Nguyen، نويسنده , , Vu T. and Wijesekera، نويسنده , , Charmi and Khan، نويسنده , , Aameera and Chandraratna، نويسنده , , P.Anthony N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
3
From page :
923
To page :
925
Abstract :
In this pilot study, we used transthoracic echocardiography to measure coronary sinus blood flow in 15 patients before and after coronary artery bypass grafting. Coronary sinus blood flow before and after revascularization was 274 ± 95 and 451 ± 102 ml/min, respectively (p <0.001). This finding is consistent with those previously demonstrated by invasive techniques.
Journal title :
American Journal of Cardiology
Serial Year :
2004
Journal title :
American Journal of Cardiology
Record number :
1897299
Link To Document :
بازگشت