• Title of article

    Usefulness of quantitative gated single-Photon emission computed tomography to evaluate ventricular synchrony in patients receiving biventricular pacing

  • Author/Authors

    Hideki Tsurugaya، نويسنده , , Hideki and Tada، نويسنده , , Hiroshi and Toyama، نويسنده , , Takuji and Naito، نويسنده , , Shigeto and Adachi، نويسنده , , Hitoshi and Seki، نويسنده , , Ryo-taro and Nogami، نويسنده , , Akihiko and Hoshizaki، نويسنده , , Hiroshi and Kurabayashi، نويسنده , , Masahiko and Oshima، نويسنده , , Shigeru and Taniguchi، نويسنده , , Koichi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    4
  • From page
    127
  • To page
    130
  • Abstract
    Quantitative gated single-photon emission computed tomography was performed in 10 patients before and shortly after (<1 month) receiving biventricular pacing (BVP). They were divided into 2 groups (responder and nonresponder groups) on the basis of clinical status and echocardiographic parameters 18 ± 6 months later. In the responder group, left ventricular synchrony shortly after BVP improved significantly compared with that before BVP (p <0.05), but there was no change in the nonresponder group.
  • Journal title
    American Journal of Cardiology
  • Serial Year
    2004
  • Journal title
    American Journal of Cardiology
  • Record number