Airoldi، نويسنده , , Flavio and Rogacka، نويسنده , , Renata and Briguori، نويسنده , , Carlo and Chieffo، نويسنده , , Alaide and Carlino، نويسنده , , Mauro and Montorfano، نويسنده , , Matteo and Mikhail، نويسنده , , Ghada and Iakovou، نويسنده , , Ioannis and Michev، نويسنده , , Iassen and Vitrella، نويسنده , , Giancarlo and Albiero، نويسنده , , Remo and Colombo، نويسنده , , Antonio، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
4
From page
1297
To page
1300
Abstract
Sixty in-stent restenotic lesions were treated with sirolimus-eluting stent implantation and retrospectively compared with a group of matched lesions treated with cutting balloon angioplasty. The results indicate a good safety profile of the procedure and a 57% reduction in the incidence of recurrent restenosis in comparison with cutting balloon angioplasty.