Title of article :
Coupling study of a novel thermocompressor driven pulse tube refrigerator
Author/Authors :
Ji، نويسنده , , Wei and Xue، نويسنده , , Xiaodai and Wang، نويسنده , , Junjie and Zhou، نويسنده , , Yuan and Chen، نويسنده , , Liubiao and Zhu، نويسنده , , Wenxiu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
The impedance match is important for the efficiency and available acoustic power of thermocompressor (TCP). The filling pressure, hot end temperature, reservoir volume and opening of orifice were changed to test the optimum load impedance for the maximum acoustic power by RC (Resistor and Capacitor) load method. To make use of the acoustic power efficiently, a pulse tube refrigerator (PTR) was designed based on this impedance to match the TCP and relative coupling experiments were conducted for the first time. The refrigerating performance of PTR was observed and the lowest no-load temperature of 70.4 K was obtained at its optimum working frequency 5.6 Hz. Also, the performance characteristics and total impedances of three different PTRs were compared to verify the rationality of the impedance matching method in this paper. The calculation results agree well with the substantial experiments and further optimization methods were also proposed.
Keywords :
Acoustic power , Impedance matching method , Thermocompressor , pulse tube refrigerator
Journal title :
Applied Thermal Engineering
Journal title :
Applied Thermal Engineering