Title of article :
Analysis of the thermal management system for a pump laser
Author/Authors :
Novak، نويسنده , , Vid and Podobnik، نويسنده , , Bo?tjan and Mo?ina، نويسنده , , Janez and Petkov?ek، نويسنده , , Rok، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
99
To page :
106
Abstract :
In this paper we report on a theoretical and experimental study of the steady-state response, transient response and efficiency of a thermal management system. We compare two alternative designs based on thermo-electric modules, the role of which is to control the temperature of the laser-diode pumping system for advanced fiber lasers. The performances of a standard pulse-width modulation controller and a variable-voltage controller were tested on a reference thermal management system. An experimental facility and a numerical model were set up, with the system response to various load conditions measured as well as numerically simulated. The results show that the design of the thermal management system based on the variable-voltage controller offers a significant performance advantage over the pulse-width modulation design.
Keywords :
thermo-electric cooler , Semiconductor laser-diode cooler , Laser pump system , Thermal management system , Pulse-width modulation controller , Variable-voltage controller