Title of article :
Analysis of the thermal performance of a solar water heating system with flat plate collectors in a temperate climate
Author/Authors :
L.M. Ayompe، نويسنده , , L.M and Duffy، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
447
To page :
454
Abstract :
The thermal performance of a solar water heating system with 4 m2 flat plate collectors in Dublin, Ireland is presented in this paper. The experimental setup consisted of a commercially available forced circulation domestic scale system fitted with an automated sub-system that controlled hot water draw-offs and the operation of an auxiliary immersion heater. The system was tested over a year and the maximum recorded collector outlet fluid temperature was 70.4 °C while the maximum water temperature at the bottom of the hot water tank was 59.9 °C. The annual average daily energy collected was 19.6 MJ/d, energy delivered by the solar coil was 16.2 MJ/d, supply pipe loss was 3.2 MJ/d, solar fraction was 32.2%, collector efficiency was 45.6% and system efficiency was 37.8%. Supply pipe losses represented 16.4% of energy collected.
Keywords :
Solar water heating system , Solar controller , Temperate climate , Flat plate collector
Journal title :
Applied Thermal Engineering
Serial Year :
2013
Journal title :
Applied Thermal Engineering
Record number :
1905938