Title of article
Energy performance of a ventilated façade by simulation with experimental validation
Author/Authors
Aparicio-Fernلndez، نويسنده , , Carolina and Vivancos، نويسنده , , José-Luis and Ferrer-Gisbert، نويسنده , , Pablo and Royo-Pastor، نويسنده , , Rafael، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
8
From page
563
To page
570
Abstract
A model for a building with ventilated façade was created using the software tool TRNSYS, version 17, and airflow parameters were simulated using TRNFlow. The results obtained with the model are compared and validated with experimental data. The temperature distribution along the air cavity was analysed and a chimney effect was observed, which produced the highest temperature gradient on the first floor. The heat flux of the external wall was analysed, and greater temperatures were observed on the external layer and inside the cavity. The model allows to calculate the energy demand of the building façade proposing and evaluating passive strategies.
rresponding office building for computer laboratories located in Valencia (Spain), was monitored for a year. The thermal behaviour of the floating external sheet was analysed using an electronic panel designed for the reading and storage of data. A feasibility study of the recovery of hot air inside the façade into the building was performed. The results obtained showed a lower heating demand when hot air is introduced inside the building, increasing the efficiency of heat recovery equipment.
Keywords
Rainscreen wall , Modelling and simulation , Ventilated façade , Energy-efficient building , TRNSYS
Journal title
Applied Thermal Engineering
Serial Year
2014
Journal title
Applied Thermal Engineering
Record number
1907172
Link To Document