Title of article :
Design of an isopropanol–acetone–hydrogen chemical heat pump with exothermic reactors in series
Author/Authors :
Xu، نويسنده , , Min and Duan، نويسنده , , Yanjun and Xin، نويسنده , , Fang and Huai، نويسنده , , Xiulan and Li، نويسنده , , Xunfeng، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
445
To page :
449
Abstract :
The isopropanol–acetone–hydrogen chemical heat pump system with a series of exothermic reactors in which the reaction temperatures decrease successively is proposed. This system shows the better energy performances as compared with the traditional system with a single exothermic reactor, especially when the higher upgraded temperature is need. At the same amounts of the heat released, the work input of the compressor and the heater are both reduced notably. The results indicate that the advantages of the IAH-CHP system with exothermic reactors in series are obvious.
Keywords :
Energy performance , Chemical heat pump , Exothermic reactor , Acetone hydrogenation
Journal title :
Applied Thermal Engineering
Serial Year :
2014
Journal title :
Applied Thermal Engineering
Record number :
1908023
Link To Document :
بازگشت