Title of article :
Experimental assessment and dynamic analysis of a hybrid generator composed of an air source heat pump coupled with a condensing gas boiler in a residential building
Author/Authors :
Di Perna، نويسنده , , Costanzo and Magri، نويسنده , , Guglielmo and Giuliani، نويسنده , , Giuliano and Serenelli، نويسنده , , Giorgio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2015
Pages :
12
From page :
86
To page :
97
Abstract :
A problem with using heat pumps to heat buildings lies in the limited power available due to the need to avoid oversizing, which would reduce the life of the machine. roblem is often solved by adding an electrical heating element, but the low efficiency of such a solution makes it worthwhile to adopt a hybrid system consisting of a heat pump combined with a condensing boiler, which can operate even when the heat pumpʹs performance falls below that of the boiler. rpose of this paper is to assess the energy performance of a hybrid unit by means of dynamic simulations, comparing it with a heat pump with electrical integration in a single-family home built in the 1970s and located in Milan. revious study, the same model was used to perform a similar analysis on a Stirling microCHP unit, so the present work completes the analysis of the most innovative generators for space heating in residential buildings. mulations showed that hybrid systems can achieve a high generation efficiency whereas heat pumps with electrical integration are unable to improve on the generation efficiency of a condensing gas boiler in the case examined.
Keywords :
Energy efficiency , Heat pumps , Hybrid generator , Space heating , Defrosting
Journal title :
Applied Thermal Engineering
Serial Year :
2015
Journal title :
Applied Thermal Engineering
Record number :
1909263
Link To Document :
بازگشت