• Title of article

    Effects of the Pt loading side and cathode-biofilm on the performance of a membrane-less and single-chamber microbial fuel cell

  • Author/Authors

    Yang، نويسنده , , Shaoqiang and Jia، نويسنده , , Boyang and Liu، نويسنده , , Hong، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    6
  • From page
    1197
  • To page
    1202
  • Abstract
    In order to analyze the effect of cathode’s Pt loading side on the performance of single-chamber microbial fuel cells (MFCs), power generation of a bamboo charcoal membrane-less air-cathode MFC was examined. The maximum power outputs obtained were 0.144 and 1.16 mW, while the maximum voltage outputs were 0.400 and 0.500 V (external resistance was 500 Ω), respectively, when the Pt loading side facing to the air and to the anode chamber solution; after a long time of operation with the side of cathode loaded Pt facing to anode chamber solution, a biofilm was developed on the inner side of cathode. With the formation of this biofilm, the power outputs of MFC increased first, and then decreased to 0.8 mW; oxidation–reduction potentials (ORP) dropped first, and then achieved the level of stability. Coulombic efficiency (CE) increased at a certain extent. In addition, the impact of cathode-biofilm on the loss of water in anode chamber solution was determined.
  • Keywords
    Pt loading side , Microbial fuel cells , bamboo charcoal , Cathode-biofilm
  • Journal title
    Bioresource Technology
  • Serial Year
    2009
  • Journal title
    Bioresource Technology
  • Record number

    1916818