• Title of article

    Dynamic pressure measurements of a hot gas filter as a diagnostic tool to assess the time dependent performance

  • Author/Authors

    Rhyner، نويسنده , , Urs and Mai، نويسنده , , Robert A Leibold، نويسنده , , Hans and Biollaz، نويسنده , , Serge M.A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    9
  • From page
    72
  • To page
    80
  • Abstract
    Dynamic pressure measurements are introduced as powerful tool to detect filter failures at early stage. Data of single recleaning pulses or a time series of recleaning pulses can be used to detect filter failures and changes in filter candle conditions during commissioning and operation. High frequency sensors were used to record recleaning back pressure pulses enabling the detection of filter failures such as leakages or blockages. Changes in filter wall resistance due to patchy cleaning or depth filtration can be detected much faster with dynamic pressure measurements than with conventional differential pressure measurements. Parameters derived from dynamic pressure data were monitored over time and compared with reference data. The method complements standard pressure difference measurements. Dynamic pressure measurements were conducted at a hot gas filter applying a coupled pressure pulse (CPP) recleaning system.
  • Keywords
    Dynamic pressure measurements , Hot gas filtration , CPP , Coupled pressure pulse , Ceramic filter candles
  • Journal title
    Biomass and Bioenergy
  • Serial Year
    2013
  • Journal title
    Biomass and Bioenergy
  • Record number

    1918103