The effect of organic loading rate on foam initiation during mesophilic anaerobic digestion of municipal wastewater sludge
Author/Authors
Ganidi، نويسنده , , Nafsika and Tyrrel، نويسنده , , Sean and Cartmell، نويسنده , , Elise، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
7
From page
6637
To page
6643
Abstract
The impact of increasing organic load on anaerobic digestion foaming was studied at both full and bench scale. Organic loadings of 1.25, 2.5 and 5 kg VS m−3 were applied to bench-scale digesters. Foaming was monitored at a full scale digester operated in a comparable organic loading range over 15 months. The bench scale batch studies identified 2.5 kg VS m−3 as a critical threshold for foam initiation while 5 kg VS m−3 resulted in persistent foaming. Investigation of a full scale foaming event corroborated the laboratory observation that foaming may be initiated at a loading rate of ⩾2.5 kg VS m−3. Experimental findings on foam composition and differences in the quality characteristics between foaming and non-foaming sludges indicated that foam initiation derived from the combined effect of the liquid and gas phases inside a digester and that the solids/biomass ultimately stabilized foaming.
Keywords
organic loading , Anaerobic digestion , Foaming , Sludge , filaments
Journal title
Bioresource Technology
Serial Year
2011
Journal title
Bioresource Technology
Record number
1924497