Title of article
Tropical mangrove sediments as a natural inoculum for efficient electroactive biofilms
Author/Authors
Salvin، نويسنده , , Paule and Roos، نويسنده , , Christophe and Robert، نويسنده , , Florent، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
7
From page
45
To page
51
Abstract
Chronoamperometry is known to be an efficient way to form electroactive biofilms (EAB) on conductive electrodes. For the first time, tropical mangrove sediments are analyzed as a potential inoculum to form MFC anodes with the use of acetate as substrate. The performance of the EAB-coated carbon cloth electrodes are evaluated according to the maximal current density, the coulombic efficiency and the cyclic voltammogramms. Working electrodes (WE) polarized at −0.2 V/SCE gave better results compared to −0.4 V/SCE and 0.0 V/SCE. The maximal current density attained was 12 A/m2 with a CE of 24%. Contributions of the EAB in the generation of current were discussed and mechanisms of electronic transfer by the bacteria were discussed. Epifluorescence and SEM images showed the evolution of the biofilms on the electrode surface and the heterogeneity of the structure.
Keywords
chronoamperometry , Cyclic voltammetry , Electroactive biofilms , Microbial fuel cells , Three-electrode systems
Journal title
Bioresource Technology
Serial Year
2012
Journal title
Bioresource Technology
Record number
1929546