• Title of article

    Method development and validation for isoflavones quantification in coffee

  • Author/Authors

    Alves، نويسنده , , R.C. and Almeida، نويسنده , , I.M.C. and Casal، نويسنده , , S. and Oliveira، نويسنده , , M.B.P.P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    6
  • From page
    914
  • To page
    919
  • Abstract
    This paper reports the development and validation of an analytical method to quantify three isoflavones (daidzein, genistein and formononetin) in coffee beans and coffee brews, by HPLC with diode-array detection. The aglycones were released by methanolic acid hydrolysis in the presence of the antioxidant BHT and the internal standard 2′-methoxyflavone. The method showed high correlation coefficients (r > 0.999) for standards subjected to the entire procedure. For samples, good intra- and inter-day precisions (<8%), and accuracies (recoveries of 95 ± 1% for ground coffee and 92 ± 2% for coffee brew) were achieved. Detection and quantification limits ranged from 5 to 8 ng/mL and from 14 and 25 ng/mL, respectively. The proposed method proved to be sensitive, precise and accurate.
  • Keywords
    Hydrolysis , HPLC , Isoflavones , Genistein , Formononetin , Daidzein , Coffee , Diode-array
  • Journal title
    Food Chemistry
  • Serial Year
    2010
  • Journal title
    Food Chemistry
  • Record number