Title of article :
ارزيابي مقايسه اي ضريب قابليت ارتجاع ليگاچورهاي الاستومري ارتودنسي
Author/Authors :
Jalaly ، T نويسنده Dept. of Orthodontics, Member of Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran , , Ahrari ، F نويسنده Dept. of Orthodontics, Member of Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran , , Zebarjad ، M نويسنده Dept. of Metallurgy, School of Engineering, Ferdosi University of Mashhad, Mashhad, Iran ,
Issue Information :
فصلنامه با شماره پیاپی 21 سال 1387
Pages :
9
From page :
310
To page :
318
Abstract :
بيان مساله: يكي از روش‌هاي بستن آرچ واير به براكت‌هاي ارتودنسي، استفاده از ليگاچورهاي الاستومري است. آگاهي از ضريب قابليت ارتجاع اين ليگاچورها، براي انتخاب گونه اي ويژه از ليگاچور در يك وضعيت باليني ويژه سودمند خواهد بود. هدف: هدف از اين بررسي، مقايسه ي ضريب قابليت ارتجاع ليگاچورهاي الاستومري هفت شركت گوناگون در حالت آغازين و پس از 28 روز نگهداري در محيط دهاني تقليد شده، بود. همچنين، تغييرات ايجاد شده در ضريب قابليت ارتجاع هر گونه ليگاچور الاستومري مورد بررسي، پس از 28 روز نگهداري بررسي گرديد. مواد و روش: در اين بررسي تجربي- آزمايشگاهي، ليگاچورهاي الاستومري شفاف هفت شركت مختلف برگزيده شدند و ضريب قابليت ارتجاعي آنها در دو حالت «آغازين» و «پس از 28 روز نگهداري در محيط دهاني تقليد شده»، با استفاده از دستگاه Zwick و با سرعت كراس هد پنج ميلي متر در دقيقه اندازه گيري گرديد. داده ها با استفاده از نرم افزار SPSS و آزمون هاي آماري ANOVA ، دانكن و Studentʹs T-test، واكاوي شدند. يافته ها: تفاوت هاي معنادار در ضريب قابليت ارتجاعي ليگاچورهاي الاستومري شركت هاي گوناگون، هم در حالت آغازين و هم پس از 28 روز نگهداري در محيط دهاني تقليد شده وجود داشت (05/0 p < ). ليگاچورهاي American Orthodontics و Ortho Technology كمترين و ليگاچورهاي Dentaurum بيشترين ميزان ضريب قابليت ارتجاعي را در حالت آغازين نشان دادند. پس از 28 روز نگهداري در محيط دهاني تقليد شده ضريب قابليت ارتجاعي در ليگاچورهايAmerican Orthodontics ، Ortho Technology و ITO به گونه‌اي چشمگير افزايش و در ليگاچورهاي Dentaurum به گونه اي معنادار كاهش يافت (05/0 p < ). نتيجه گيري: ليگاچورهاي American Orthodontics و Ortho Technology براي استفاده ي بي درنگ پس از باندينگ ارتودنسي و نيز، در مكانيك‌هاي اسلايدينگ (Sliding) مناسب هستند، در حالي كه، ليگاچورهاي Dentaurum براي استفاده ي بي درنگ پس از باندينگ ارتودنسي مناسب نيستند.
Abstract :
Statement of problem: The application of elastomeric ligatures is one of the methods of archwires ligation to orthodontic brackets. Knowledge about modulus of elasticity of these ligatures is useful for selecting a specific brand of elastomeric ligature for a special condition. Purpose: The purpose of this study was to compare elastic modulus of seven commercially available elastomeric ligatures in the initial condition and after 28 days immersion in a simulated oral environment. Changes in the modulus of elasticity was also surveyed for each brand of ligatures after 28 days. Materials and Method: In this experimental laboratory-based study, elastomeric ligatures were obtained from different companies and their modulus of elasticity were measured in the initial condition and after 28 days immersion in a simulated oral environment using Zwick testing machine at 5mm/min cross head speed. The data were analyzed using SPSS software and ANOVA, Duncan and studentʹs t-test. Results: Different brands of elastomeric ligatures showed significant differences in elastic modulus both in the as-received condition and after 28 days immersion in the simulated oral environment (p < 0.05). Ligatures from American Orthodontics and Ortho Technology showed the lowest and ligatures from Dentaurum revealed the highest elastic modulus in the as-received condition. Modulus of elasticity in the ligatures from American Orthodontics, Ortho Technology and ITO increased significantly while in ligatures from Dentaurum it was decreased significantly after 28 days immersion in the simulated oral environment (p < 0.05). Conclusion: Ligatures from American Orthodontics and Ortho Technology are suitable for immediate use after bonding and in sliding mechanics while ligatures from Dentaurum are not suitable to use immediately after bonding. Key words: Elastomeric ligatures, Elastic Modulus, Bonding
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Serial Year :
1387
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Record number :
1968918
Link To Document :
بازگشت