Title of article :
Effect of phospholipid insertion on arrayed polydiacetylene biosensors
Author/Authors :
Kim، نويسنده , , Kyung-Woo and Choi، نويسنده , , Hyun and Lee، نويسنده , , Gil Sun and Ahn، نويسنده , , Dong June and Oh، نويسنده , , Min-Kyu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Micro-arrayed polydiacetylene (PDA) vesicles mixed with phospholipids on glass slides were prepared for label-free detection of Escherichia coli. When E. coli bound to its antibodies chemically attached to polydiacetylene, the fluorescence of the vesicles was dramatically increased. The insertion of dimyristoyl phosphatidylcholine (DMPC) in the vesicles drastically reduced the response time for the fluorescence changes. Vesicles with 20–30% DMPC provided optimal results for bacterial detection. Fourier transform infrared (FTIR) spectra analysis suggested that DMPC insertion decreased the strength of hydrogen bonding among the amide and carboxylic acid groups of the polydiacetylene vesicles. Reduced bonding strength resulted in less rigid structure of the polydiacetylene polymer, allowing more rapid detection upon molecular recognition.
Keywords :
Label-free biosensor , Bacteria sensor , FTIR , Dimyristoyl phosphatidylcholine (DMPC) , Polydiacetylene
Journal title :
Colloids and Surfaces B Biointerfaces
Journal title :
Colloids and Surfaces B Biointerfaces