• Title of article

    Development and validation of the high performance liquid chromatography–ion exclusion method for detection of lactic acid in milk

  • Author/Authors

    Milagres، نويسنده , , Maria Patricia and Brandمo، نويسنده , , Sebastiمo César Cardoso and Magalhمes، نويسنده , , Mirella Araujo and Minim، نويسنده , , Valéria Paula Rodrigues and Minim، نويسنده , , Luis Antonio، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    5
  • From page
    1078
  • To page
    1082
  • Abstract
    The present work reports the development and validation of an analytical method for lactic acid quantification in milk by ion exclusion–HPLC with UV detection. This method showed good precision (variation coefficient <7.0%) and good accuracy (97.6–99.6%). Calibration curves were linear (R2 > 0.996) at the tested range of 5.0–25.0 mmol L−1; and the detection and quantification limits were 0.5 and 1.0 mmol L−1, respectively. Analysis of lactic acid in fermented milk (FM) or NaOH neutralised fermented milk (FNM) was performed using samples obtained during 9 h of fermentation. An ANOVA analysis combined with the Tukey test was used to show that the method was insensitive to the differences between FM and FNM. The proposed method therefore proved to be a useful quality control tool in laboratories because it was able to determine milk acidity even in adulterated samples.
  • Keywords
    Ion exclusion , Method development , milk , lactic acid , High-performance liquid chromatography , Method validation
  • Journal title
    Food Chemistry
  • Serial Year
    2012
  • Journal title
    Food Chemistry
  • Record number