• Title of article

    HPLC and UPLC methods for the determination of zearalenone in noodles, cereal snacks and infant formula

  • Author/Authors

    Ok، نويسنده , , Hyun Ee and Choi، نويسنده , , Sung-Wook and Kim، نويسنده , , Meehye and Chun، نويسنده , , Hyang Sook، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    6
  • From page
    252
  • To page
    257
  • Abstract
    High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 μg kg−1 and 2.5 and 8.3 μg kg−1, respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 μg kg−1 by HPLC and 3.1 to 17.6 μg kg−1 by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity.
  • Keywords
    HPLC , UPLC , infant formulas , Zearalenone , Cereal snacks , Noodles
  • Journal title
    Food Chemistry
  • Serial Year
    2014
  • Journal title
    Food Chemistry
  • Record number

    1978589