Title of article :
Stability indicating HPLC–UV method for detection of curcumin in Curcuma longa extract and emulsion formulation
Author/Authors :
Syed، نويسنده , , Haroon Khalid and Liew، نويسنده , , Kai Bin and Loh، نويسنده , , Gabriel Onn Kit and Peh، نويسنده , , Kok Khiang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2015
Pages :
6
From page :
321
To page :
326
Abstract :
A stability-indicating HPLC–UV method for the determination of curcumin in Curcuma longa extract and emulsion was developed. The system suitability parameters, theoretical plates (N), tailing factor (T), capacity factor (K′), height equivalent of a theoretical plate (H) and resolution (Rs) were calculated. Stress degradation studies (acid, base, oxidation, heat and UV light) of curcumin were performed in emulsion. It was found that N > 6500, T < 1.1, K′ was 2.68–3.75, HETP about 37 and Rs was 1.8. The method was linear from 2 to 200 μg/mL with a correlation coefficient of 0.9998. The intra-day precision and accuracy for curcumin were ⩽0.87% and ⩽2.0%, while the inter-day precision and accuracy values were ⩽2.1% and ⩽−1.92. Curcumin degraded in emulsion under acid, alkali and UV light. In conclusion, the stability-indicating method could be employed to determine curcumin in bulk and emulsions.
Keywords :
Stability indicating HPLC–UV method , Curcumin , System suitability , Stress degradation study