Title of article
Performance of a scintillating fibres semiprojective electromagnetic calorimeter
Author/Authors
Bertino، نويسنده , , M. and Bini، نويسنده , , C. and De Zorzi، نويسنده , , G. and Diambrini Palazzi، نويسنده , , G. and Di Cosimo، نويسنده , , G. and Di Domenico، نويسنده , , A. and Garufi، نويسنده , , F. and Gauzzi، نويسنده , , P. and Zanello، نويسنده , , D.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
6
From page
363
To page
368
Abstract
A highly segmented scintillating fibres/lead electromagnetic calorimeter has been tested. Each calorimeter module has semiprojective geometry and is shaped as a wedge with an angle of (0.82)°. The fibres are however parallel to the wedge axis and the two small lateral regions are not fibre-instrumented. This simple and cheap approach to a projective geometry allows to achieve still good energy and space resolution. Results with electrons in the range 10–100 GeV are presented.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1995
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
1993939
Link To Document