Low-cost electron-gun pulser for table-top maser experiments
Author/Authors
Grinberg، نويسنده , , V. and Jerby، نويسنده , , E. and Shahadi، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
4
From page
327
To page
330
Abstract
A simple 10 kV electron-gun pulser for small-scale maser experiments is presented. This low-cost pulser has operated successfully in various table-top cyclotron-resonance maser (CRM) and free-electron maser (FEM) experiments. It consists of a low-voltage capacitor bank, an SCR control circuit and a transformer bank (car ignition coils) connected directly to the e-gun. The pulser produces a current of 3 A at 10 kV voltage in a Gaussian like shape of 1 ms pulse width. The voltage sweep during the pulse provides a useful tool to locate resonances of CRM and FEM interactions. Analytical expressions for the pulser design and experimental measurements are presented.