Title of article :
The wide gap resistive plate chamber
Author/Authors :
Crotty، نويسنده , , I and Cerron Zeballos، نويسنده , , E and Lamas Valverde، نويسنده , , Ch. and Hatzifotiadou، نويسنده , , D and Williams، نويسنده , , M.C.S and Zichichi، نويسنده , , A، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
9
From page :
512
To page :
520
Abstract :
The resistive plate chamber (RPC) has good time and position resolution; these factors (coupled to its simple construction) make it an attractive candidate for muon trigger systems at future colliders. However, operated in spark mode, the RPC has severe rate problems that make it unusable above 10 Hz/cm2. We have previously published our results concerning the operation of the RPC in spark and in avalanche mode; we have shown that the rate limit can be increased to 150 Hz/cm2 if the RPC is operated in avalanche mode. Here, we discuss the performance of chambers with 6 and 8 mm gas gaps (compared to the more usual 2 mm gap). We outline the reasons for this choice, and also discuss anode versus cathode strip readout. We have measured the efficiency versus flux, and also show that an enhanced rate limit can be obtained if only a small region of the chamber is exposed to the beam (spot illumination). Finally we have tested the performance of chambers constructed with other materials for the resistive plate and compare it to chambers constructed with our preferred plastic, melamine laminate.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1995
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
1994951
Link To Document :
بازگشت