Title of article :
Performance of SRRC 1.3 GeV electron booster synchrotron
Author/Authors :
Lin، نويسنده , , K.K and Hsu، نويسنده , , K.T and Ueng، نويسنده , , T.S. and Chiou، نويسنده , , J.P. and Hwang، نويسنده , , J.I and Liu، نويسنده , , Y.C and Modeer، نويسنده , , J، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
12
From page :
1
To page :
12
Abstract :
The characteristics and the performance of SRRC 1.3 GeV electron booster synchrotron are described in this report. Operation parameters, such as synchrotron tune, betatron tune, momentum compaction factor, betatron function, chromaticity etc. were measured at injection energy, 50 MeV, DC mode; and compared with calculated results at a tune of vx = 4.40, vy = 2.43. The tune drift and the bunch length variation of accelerated beam have been studied. The energy spread and the beam emittance variation during ramping were derived. The diagnostics instrumentation used in this experiment was described. Comparison between experimental results and theoretical expectations is presented.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1995
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
1994967
Link To Document :
بازگشت