Title of article
Measurement of input beam emittance to obtain MeV, mA-class heavy ion beams in a VERFQ linac
Author/Authors
Susumu Tokiguchi، نويسنده , , Katsumi and Amemiya، نويسنده , , Kensuke and Ito، نويسنده , , Junya and Sato، نويسنده , , Tadasi and Yamada، نويسنده , , Satoru and Hirao، نويسنده , , Yasuo and Tokuda، نويسنده , , Noboru، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
6
From page
153
To page
158
Abstract
To obtain mA-class beams which can assure high throughput in an MeV ion implantation process, a high current ion beam injection system and a variable energy radio frequency quadrupole (VERFQ) linac driven by an external LC-resonance electric circuit were constructed. A newly designed computer controlled emittance monitor was installed, and the horizontal and vertical normalized emittances of the input beam were simultaneously measured.
rmalized emittances of P+ ion beams were comparable to the designed RFQ acceptance (0.05 π cm · mrad). However, the P2+ ion beams had a horizontal emittance that was about twice as large as the acceptance. By adjusting the emittance diagram so that the beam current fit the acceptance was maximized, the P+ and P2+ currents of 1 emA (electric mA) were obtained at energies of 1 MeV and 2 MeV under the cw operation condition, respectively.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1995
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
1995617
Link To Document