Title of article :
A CsI(pure) calorimeter for π0 detection at intermediate energies
Author/Authors :
Okuno، نويسنده , , H. and Imanishi، نويسنده , , A. and Maruyama، نويسنده , , K. and Morimoto، نويسنده , , T. and Nakayoshi، نويسنده , , K. and Watanabe، نويسنده , , K. and Kubota، نويسنده , , J. and Nakamura، نويسنده , , T. and Terachi، نويسنده , , Y. and Emura، نويسنده , , T. and Sawamoto، نويسنده , , T. and Shimizu، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
9
From page :
352
To page :
360
Abstract :
A set of CsI(pure) crystals have been tested for use as an electromagnetic calorimeter for π0 detection in photonuclear reactions at photon energies below 1.2 GeV. Performances of the calorimeter including energy and position resolution are studied by using the electron and tagged-photon beams at the INS-Tokyo electron synchrotron. In the first experiment for the nuclear coherent π0 photoproduction carried out at INS, a π0 mass resolution of 7 MeV (rms) has been obtained in the π0 energy region between 0.5 and 1.0 GeV.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1995
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
1996020
Link To Document :
بازگشت