Author/Authors :
Perdrisat، نويسنده , , C.F. and Day، نويسنده , , A. and Koechner، نويسنده , , D. and Kross، نويسنده , , B. and Majewski، نويسنده , , S. and Pourang، نويسنده , , R. and Punjabi، نويسنده , , V. and Raine، نويسنده , , John D. and Weisenberger، نويسنده , , A. and Wilson، نويسنده , , C.D. and Wojcik، نويسنده , , R. and Zorn، نويسنده , , C.، نويسنده ,
Abstract :
Several applications of two Hamamatsu position sensitive photomultiplier tubes to the detection of high energy particles with scintillating fibers are discussed. The PMTs are of the multiwire anode grid design, type R2486 and R4135. These tubes were tested with both single samples and arrays of 2 and 3 mm diameter scintillating fibers. Measurements of position resolution of the PMTs using either the charge digitization or the delay line readout techniques were made. The results indicate an intrinsic inability of the technique to reconstruct the actual position of a fiber on the photocathode when its location falls halfway between two grid wires. A way to overcome this limit is suggested.