Title of article :
Optimization of the readout electronics for a superheated superconducting granule particle detector
Author/Authors :
Borer، نويسنده , , K. and Furlan، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Abstract :
The sensitivity of Superheated Superconducting Granule (SSG) detectors is limited by the detectability of phase transition of single granules. The corresponding voltage pulse induced by the magnetic flux change in a pick-up coil was measured with an amplifier at room temperature. The readout circuit was optimized on the basis of a simple theoretical noise model, and a signal-to-noise ratio close to the expected theoretical limit was achieved. The minimal granule size required for a detectable signal has been determined as a function of the pick-up coil volume.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A