Title of article :
The Mark III IR FEL: improvements in performance and operation
Author/Authors :
Barnett، نويسنده , , G.A. and Madey، نويسنده , , J.M.J. and McKee، نويسنده , , C.B. and Straub، نويسنده , , K.D. and Szarmes، نويسنده , , E.B.، نويسنده ,
Pages :
3
From page :
97
To page :
99
Abstract :
The Mark III has been improved both by the installation of a new thermionic microwave gun and added capabilities. The new electron gun yields a reduced emittance and allows operation at a higher repetition rate and an increased electron macropulse length. We have added the capability to tailor the input microwave pulse by adding a ramp or a step onto the macropulse. Phased-locked operation has been used to produce tunable optical radiation with filtered spectral widths of 200 MHz. Both phase-locking and hole-coupling have been used to increase the outcoupling efficiency. The RF system of the Mark III is now phase-locked to the RF system of the adjacent storage ring driver for the short-wavelength FEL sources of the laboratory, making possible two-color UV-IR pump-probe experiments.
Journal title :
Astroparticle Physics
Record number :
1998033
Link To Document :