Author/Authors :
Frenje، نويسنده , , J. and Conroy، نويسنده , , S. and Ericsson، نويسنده , , G. and Kنllne، نويسنده , , J. and Renberg، نويسنده , , P-U. and Traneus، نويسنده , , E.، نويسنده ,
Abstract :
Deuterated scintillators are proposed as detectors in neutron spectrometers based on the proton recoil method as a means to reduce the interference from background. Specifically, the use of a deuterated scintillator hodoscope in the focal plane of a magnetic proton recoil spectrometer is considered. The response of the hodoscope to signal protons and background neutrons is determined with Monte Carlo simulations and measurements with a 239PuBe source. The results are discussed relative to the use of regular hydrogen based scintillators with an assessment of the expected gain in a focal plane detector for fusion neutron applications.
Keywords :
Deuterated scintillators , Neutron diagnostics , neutron background , Signal recoil protons , Scintillator response