Title of article :
Glow curve analysis of TLD-700 dosimeters exposed to fast neutrons and gamma rays from isotopic sources
Author/Authors :
Mukherjee، نويسنده , , Bhaskar، نويسنده ,
Pages :
4
From page :
179
To page :
182
Abstract :
Batches of TLD-700 chips were irradiated with the fast neutrons from 241AmBe and 252Cf sources, energy degraded neutrons from the 241AmBe source moderated by light water and gamma rays from a 137Cs source. The net area under the deconvoluted high temperature (≈300°C) peak of neutron irradiated chips was observed to increase with the average neutron energy. A technique for the estimation of average neutron energy from the area under the deconvoluted high temperature glow peak is suggested.
Journal title :
Astroparticle Physics
Record number :
2000361