Author/Authors :
Barrette، نويسنده , , J and Dai، نويسنده , , Y and Filimonov، نويسنده , , K and Gan، نويسنده , , D and Mark، نويسنده , , S.K and Qi، نويسنده , , Y.J and Rosati، نويسنده , , M and Starinski، نويسنده , , N and Wang، نويسنده , , M and Zhang، نويسنده , , B and Yu، نويسنده , , B and Libby، نويسنده , , B، نويسنده ,
Abstract :
An investigation of MWPCs with interpolating chevron shaped cathode pad readout has been carried out as part of the R&D for the particle tracking system of the PHENIX detector at RHIC. Two prototype chambers were designed and constructed. Their response to minimum ionizing particles was tested with secondary beams from the AGS accelerator system at the Brookhaven National Laboratory. Results on resolution, differential non-linearity and overall performance for different chevron patterns and cell geometries are presented.