Title of article
New analysis and performance of a wall-current monitor
Author/Authors
Suwada، نويسنده , , T and Tamiya، نويسنده , , K and Urano، نويسنده , , T and Kobayashi، نويسنده , , H and Asami، نويسنده , , A، نويسنده ,
Pages
8
From page
1
To page
8
Abstract
A new wall-current monitor has been developed in order to reinforce the beam-monitoring system in the PF 2.5-GeV linac for the KEK B-Factory. A prototype monitor was tested for its performance and characteristics. The experimental results in terms of both bench tests and beam tests by single-bunch electron beams were analyzed on the basis of equivalent-circuit models. The frequency response of the monitor agreed well with a lumped equivalent-circuit model for both time- and frequency-domain measurements. The position dependence and its frequency characteristics of the monitor also agreed well with a distributed equivalent-circuit model for both time- and frequency-domain measurements. The rise time of the monitor was about 3 ns, which indicated a poor response for short-pulse beams (< 1 ns). The reason could be attributed to the stray inductance of the ceramic solid resistor and not very good frequency response of the ferrite core.
Journal title
Astroparticle Physics
Record number
2002514
Link To Document