Title of article :
Evidence for charge collection efficiency recovery in heavily irradiated silicon detectors operated at cryogenic temperatures
Author/Authors :
Palmieri، نويسنده , , Vittorio Giulio and Borer، نويسنده , , Kurt and Janos، نويسنده , , Stefan and Da Viل، نويسنده , , Cinzia and Luca Casagrande، نويسنده ,
Pages :
4
From page :
475
To page :
478
Abstract :
Charge collection efficiency of 300 μm thick silicon detectors, previously irradiated at 2.23×1015 n/cm2, has been measured at 4.2, 77 and 195 K. The recovery measured at a bias voltage of 250 V leads to a most probable signal for minimum ionizing particles of 13 000 electrons, preserving its fast characteristics (<5 ns). Negligible difference is observed between 77 and 4.2 K operation, while no recovery is measurable at 195 K. The samples were stored at room temperature and cooled only when operated.
Journal title :
Astroparticle Physics
Record number :
2005989
Link To Document :
بازگشت