Title of article :
Design parameter investigation of industrial size ultrasound textile treatment bath
Author/Authors :
Perincek، نويسنده , , Seher and Uzgur، نويسنده , , A. Erman and Duran، نويسنده , , Kerim and Dogan، نويسنده , , Aydin and Korlu، نويسنده , , Aysegul E. and Bahtiyari، نويسنده , , ?brahim M.، نويسنده ,
Pages :
6
From page :
184
To page :
189
Abstract :
Design requirements for industrial size ultrasound bath for textile treatments have been determined. For this purpose, effects of sound pressure level, bath temperature, bath volume, textile material type and hydrophility degree of fabric were examined extensively. Finite element analysis (FEA) was used to investigate spacing and alignment of the ultrasound source transducers to reach effective and homogenous acoustic pressure distribution in the bath. It was found that textile material type, bath temperature and volume led to significant changes at sound pressure level. These parameters should be taken into consideration in designing of industrial size ultrasound bath for textile treatments. Besides, wettability of textiles is highly dependent to the distance from the transducers.
Keywords :
Textile treatment , Ultrasound , Finite element analysis
Journal title :
Astroparticle Physics
Record number :
2006450
Link To Document :
بازگشت