Abstract
It is shown that ratio of 116mIn and 115mIn activities, simultaneously produced by neutron capture and photoexcitation of 115mIn, could be very sensitive index for control of the end-point energy of therapy accelerator X-ray beams. The presented method can be used from 7 MeV where begins production of photoneutrons.