Title of article
Method for mapping charge pulses in semiconductor radiation detectors
Author/Authors
Prettyman، نويسنده , , T.H.، نويسنده ,
Pages
6
From page
232
To page
237
Abstract
An efficient method for determining the distribution of charge pulses produced by semiconductor detectors is presented. The method is based on a quasi-steady-state model for semiconductor detector operation. A complete description of the model and the underlying assumptions are given. Mapping of charge pulses is accomplished by solving an adjoint carrier continuity equation. The solution of the adjoint equation yields Greenʹs function, a time- and position-dependent map that contains all possible charge pulses that can be produced by the detector for charge generated at discrete locations (e.g., by gamma-ray interactions). Because the map is generated by solving a single, time-dependent problem, the potential for reduction in computational effort over direct mapping methods is significant, particularly for detectors with complex electrode structures. In this paper, the adjoint model is presented and the mapping method is illustrated for a simple case.
Journal title
Astroparticle Physics
Record number
2008084
Link To Document