• Title of article

    Improvement of field quality of Glaser magnets used for focusing ion beams

  • Author/Authors

    Sarma، نويسنده , , P.R and Pattanayak، نويسنده , , S.K and Bhandari، نويسنده , , R.K، نويسنده ,

  • Pages
    6
  • From page
    243
  • To page
    248
  • Abstract
    Glaser magnets used for focusing charged particle beams show appreciable aberrations. These aberrations can be reduced by increasing the pole gap, which, however, reduces the focal power also. We have shown that a better way of improving the field quality in Glaser magnets is to taper the poles outwards. The saturation characteristics also are better in tapered poles.
  • Keywords
    Aberrations , Quadrupoles , Glaser magnets , Field quality improvement
  • Journal title
    Astroparticle Physics
  • Record number

    2008798