Author/Authors :
Kanazawa، نويسنده , , M. and Sato، نويسنده , , K. and Itano، نويسنده , , A. and Sudou، نويسنده , , M. and Noda، نويسنده , , K. and Takada، نويسنده , , E. and Kumada، نويسنده , , M. and Yamazaki، نويسنده , , C. and Yamagishi، نويسنده , , T. and Morii، نويسنده , , Y. and Toyoda، نويسنده , , E. and Tsuzuki، نويسنده , , N. and Yagi، نويسنده , , T.، نويسنده ,
Abstract :
An RF acceleration system, in which digital control with a direct digital synthesizer (DDS) is applied, has been developed for the Heavy Ion Medical Accelerator in Chiba (HIMAC) synchrotron. This digital system allows us to obtain stable operation of the acceleration system over a wide frequency range from 1.04 to 7.9 MHz. In this paper the designed digital RF control system and its performance are described.
Keywords :
Feedback , Heavy-ion therapy , Acceleration system , Direct digital synthesize